For all of our products, we typically can get you better than MSRP pricing. Ask us for a quote so we can get you the discount.
Get unmatched power distribution in a highly compact footprint with Eaton’s Remote Power Panel (RPP). This highly customizable unit offers a choice of standard or rack depth cabinets with up to four-panel boards, each with 42 circuit breakers. Big power is coupled with extensive monitoring in the RPP, down to the branch circuit level, thanks to the loaded Energy Management System to ensure easy and effective power management.
*Ask us for a quote for discounted pricing.
Reduce installation time and save startup costs
Extend branch circuit monitoring with an integrated Emergency Management System
Made to take advantage of white space
Product snapshot
208/120V or 400V versions, 3 phase
Standard or rack depth cabinet sizes
Direct connection to panelboard breakers (225A or 400A)
225A or 400A column panelboards
Front: 2 panelboards
Rear: 2 panelboards
Up to 168 pole positions
Factory-installed breakers
Dimensions, W x D x H
Electrical characteristics
208/120V: 3 phase, 4 wire + ground
400V: 3 phase, 4 wire + ground
450/900A
Single feed into main lug (up to 4)
Dual feed into main lug (up to 4)
Direct connection to panelboard main breaker
60 Hz
200%
Power distribution, 208/120V
Up to (4) 42-pole panels
(2) panels in front & (2) panels in rear
Cutler-Hammer (Bolt-on or Plug-in) or SquareD panels (225A or 400A main breakers)
80% or 100% rated
Factor-installed branch circuit breakers
Standards
NEMA
UL60950
CSA60950
Options
- Energy Management System
- High kAIC Panel main breakers
- 100% rated sub-feed breakers (CH)
- 100% rated panel main breakers (CH)
- Branch circuit monitoring
- Floor stands: seismic rated (12″, 18″, 24″, 30″, 36″ & 48″)
- Isolated gound (standard)
- Distributed cables (whips)
- Clear Plexiglas doors
- Isolated barrier for dual feed input and direct connect
- Top or bottom panelboard installation
- Extra knock-out, incoming and conduit plates
- Transient suppression plate
- Surge protection device (100 or 200kA)
- Low voltage control junction box
- Mesh rack doors
- 4 building alarm inputs (N/O or N/C)
Energy Management System
Monitored parameters
- Input voltage (L-L & L-N)
- Input current (A, B & C phases)
- Output voltage (L-L & L-N)
- Output current (A, B & C phases)
- Output neutral current
- System ground current
- kVA, kW, Hz
- Monthly, yearly, total kWH
- Output voltage THD (all phases)
- Power factor (lead/lag indicator)
- Output current % (A, B & C phases)
Captures highest and lowest reading on a monthly basis with trend information over the last 24 hours.
- Input/output voltage
- Input/output current
- Input/output frequency
- Input/output power factor
- Input/output kVA
- Input/output voltage THD
- Ground current
- Neutral current
- Input/output over- & under-voltage
- Input/output over- & under-frequency
- Input/output phase rotation
- Input/output voltage THD
- Input/output current THD
- Output overload (3 levels)
- Building alarms (4 programmable)
- Summary alarm
- Communication fault
Reviews